A template-driven inspection and test-records engine for manufacturers and fabricators. Pick a test — weld visual, bend, wall-tie load, galvanising coating, tensile or proof-load, electrical certificates, F-Gas — and InspectIQ builds the form, the certificate and the batch report from the same template, with your pass limits pre-filled from a Product Library. Every record is operator-stamped and certificate-numbered on a tamper-evident audit trail. Runs standalone or inside AssureIQ and TradeIQ. iPhone app on the App Store; Android built from the same code.
From £2,500 implementation + £150 / month, excluding VAT · three-year term, first year in advance · how pricing works
Works with what you already have: Product Library and batch data from your spreadsheet (CSV/XLSX); certificates and DoP drafts as PDF; QR labels for traceability.
Where your data lives: On your own device by default — nothing is sent to us. Hosted team mode gives your whole inspection team per-user sign-in, role-based access (owner/admin/editor) and one shared, live record — synced to the same UK database (Supabase, London, eu-west-2) the iPhone/Android app reads from, so a certificate raised on the shop floor shows up for the office the same moment. Security & trust →
Straight answer: Test standards define the method; acceptance limits come from the product standard, your specification or the customer. InspectIQ records and certifies against them — it is not a certification body and does not replace your inspector's competence.

Capture photo evidence, run the test and certify on site, even offline — then print or share the QR-verified certificate straight from your phone or tablet.
A real walkthrough of InspectIQ — test, certify, and issue a tamper-evident record, start to finish.
Weld visual inspection (BS EN ISO 17637, acceptance to a BS EN ISO 5817 quality level), bend test (BS EN ISO 7438), wall-tie load (BS EN 845-1), galvanising coating (BS EN ISO 1461), tensile/proof-load (BS EN ISO 6892-1), electrical certificates (BS 7671: EIC, EICR, Minor Works), F-Gas, gas appliance safety checks (Gas Safety Regs 1998) and general inspection — the form, certificate and batch report all render from the same config. A Product Library pre-fills each test with your pass requirements, imported from CSV or straight from Excel.
Every record gets a unique, sequential Certificate No — shared across every template so nothing gets renumbered or lost.
Draft UKCA Declarations of Performance and Certificates of Conformity from your FPC and inspection records — manufacturer, AVCP system and declared-performance table pre-filled for you to check and sign.
A failed inspection can raise a non-conformance in one click — root cause, containment and CAPA owner tracked to close-out, ISO 9001 clause 10.2 style.
Every create, edit, void and print is logged and chained — tamper-evident by design, not just a changelog.
Export a self-contained certificate + full audit trail + amendment history as one file, ready to send to a customer's quality department.
Track every gauge and test instrument's last calibration, interval and due date, with an automatic overdue flag and one-click calendar export — so an auditor never finds an out-of-calibration instrument behind one of your certificates.
Pass-rate trend, fail Pareto and a live SPC run chart by product, template, operator or customer — the ISO 9001 management-review numbers, without exporting to Excel.
Metal fabricators, wall-tie and galvanising suppliers and anyone certifying to a product standard — InspectIQ replaces a folder of Word templates and a spreadsheet register with one auditable system. Unlike a general inspection/checklist app, every template already carries its acceptance standard and pulls pass/fail limits from your own Product Library — nobody's typing tolerances into a blank form. The NCR/CAPA workflow and audit trail above follow the structure ISO 9001 and ISO 14001 expect, so your records are already in a shape an auditor can work with.

The test form, the printable certificate and the batch report all come from the same template — no separate documents to keep in sync.
Attach photo evidence per inspection, then print a QR label that opens a self-checking verify card on any phone — no app required.
Embeds into AssureIQ or TradeIQ over the same customer/site list, so gas, statutory and product inspections sit in one place when you need more than one.
The same InspectIQ, wrapped as a native iOS app — inspect, certify and print a QR-verified certificate on site, even offline.



Test standards such as BS EN ISO 7438 define the method; acceptance limits come from the product standard, your specification or the customer — InspectIQ records the applicable standard against every test, then your inspector certifies against it. That's a deliberate honesty line, not a gap.
Visual testing of fusion welds — WPS and welder qualification recorded, acceptance against an ISO 5817 quality level (B/C/D).
Metal bend test method — former Ø, angle, number of bends, recorded per specimen.
Cavity wall-tie tension/compression load test, for wall-tie and masonry-connector manufacturers.
Hot-dip galvanised coating thickness/mass check for galvanised steel components.
2.1/2.2/3.1/3.2 inspection-document classification recorded on every certificate.
InspectIQ structures your inspection records to match the method defined by these standards; it is not a certification body and does not replace your own competence or quality-management judgement — confirm your specific obligations with your quality manager or notified body. Full standards breakdown →
What makes a test certificate credible: sequential numbering, operator identity, immutability, audit trails, batch reports — and where Word/Excel fails.
Read the guide → InspectIQHow ISO 9001 clause 10.2 corrective action really works: containment vs correction, root cause analysis, verifying effectiveness, and why most NCR registers never close the loop.
Read the guide →An interactive guide to InspectIQ, with real screens on sample data. Pick your kind of business and tap through.